Interactive Heat Pump Diagram

See the refrigeration circuit and the heating circuit working together — including the defrost cycle.

The cycle
Refrigerant
Cold refrigerantAbsorbing heatHot refrigerantHottest refrigerant
Heating water
Heating flowHeating return
Click any component
MONOBLOC AIR SOURCE HEAT PUMP2°C airThe complete refrigeration circuit is contained within the outdoor unit.YOUR HOMEcold liquid inwarmed vapour outOutdoor coilheat from air · frost 15%Fanpulls in airCompressorsqueezes gas → hotReversing valveHEATING positionExpansion valvedrops pressure → coldrefrig.waterhot gaswarm liquidcool inhot outHeat exchangerheat crosses, fluids never mixPumppushes water roundHeating FlowHeating Returnhot incooler outRadiatorswarms your roomswarming vapourhot gas
Live status
Heating
Outdoor air
2 °C
Flow temp
45.0 °C
Return temp
39.1 °C
Delta T
5.9 K
Heat output
5.3 kW
Estimated COP
2.52
Outdoor coil
Light frost
Suction / discharge
6.7 / 43.9 bar
Te / Tc
-5 / 50 °C
Conditions
2°C

Below about 7 °C with damp air, frost starts to form on the outdoor coil.

85%
45°C

Lower flow temperatures give a higher COP.

70%
Defrost cycle

In cold, damp weather moisture freezes onto the outdoor coil. The heat pump briefly runs backwards to melt it off.

  1. Reversing valve switches, fan stops
  2. Hot gas sent to the outdoor coil, ice melts, heating paused
  3. Valve returns, heating output ramps back up